You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 29 Next »


Overview

  • Optics have thresholds for how strong or weak of a light level they can receive before they'll theoretically fail

  • The purpose of this page is to help estimate if a particular optic will work on a particular fiber span

Terminology

  • Power level
    • The power level from optics is measured in microwatts but converted to dBm for ease of reading by humans
    • dB is on a logarithmic scale 
    • The higher the dBm the stronger your receive level
    • The lower the dBm the weaker your receive level

Estimates 

  • Ballpark estimates:
    • 0.25dB loss per kilometer for 1550nm
    • 0.5 dB loss per kilometer for 1310nm
    • 0.3 dB loss per connector

Tools & Resources 

  • DOM
  • Vendor Docs
  • OTDR
  • Power meter
    • Tool used to report the current light levels (dBm) being received 

  • Pads/Attenuators
    • Used to attenuate the light power level to be within the threshold of an optic

    • Always pad optics on the the rx ports of your optics 

      • One pad on the rx port of the hub interface, one pad on the rx port of the cpe interface

      • The RX port on an optic should be the right-hand side if the lever is facing up
    • Example images:

Calculating Loss

  1. Record the TX power of your optic
    1. Either by using DOM or a power meter
  2. Subtract the OTDR results (loss in dB)
    1. If you don't have OTDR test results, subtract the estimated loss based on the distance
  3. Subtract the connector loss (number of patches)
  4. Results
    1. Is the result within your optic's receive min -> max? 
      1. If it's above the max RX add the appropriate pad
      2. If it's below the max RX you might need a different optic or 


Example:

  1. I'm transmitting at +1dB
  2. I don't have an OTDR, but the fiber path distance is 27km
    1. Subtract 0.4 dB loss per kilometer for 1550nm at 27km, subtract 10.8dB
  3. I'm using two patch cables, one on each side of my fiber span, subtract ~1dB
  4. Result: −10.8dB
  5. My result of -10.8dB is within the -8dB to -23dB receive specification for the optic
    1. I shouldn't need a pad
    2. My optic should work

 

  • No labels